Sample pilot report · LaplaceOne research block · 27 November 2026
Should we adopt the smaller AXI skid buffer?
On the reference floorplan, the patch meets the behavior, timing and output-driver requirements while using 14.83% less standard-cell area. Adoption depends on the traffic the block will actually carry.
Engineering recommendation
Shortlist the patch for an area-constrained design at 60 × 60 µm. For a design that streams continuously and prioritizes energy per transfer, keep the upstream implementation. For mixed traffic, replay a representative system trace before deciding.
Block and acceptance criteria
We compared the upstream 32-bit AXI-Stream skid buffer and its patched RTL at 100 MHz using the Nangate45 typical library. A candidate had to preserve cycle behavior during stalls and reset, retain direct flip-flop connections to all 56 output bits, meet setup and hold timing, and reduce routed cell area at the same die dimensions.
What the engineer reviews in the patch
Upstream controls writes to the temporary and output banks separately. The patch shares a word selector between the banks. While the sink is stalled, the front bank retains its payload. This excerpt shows the selection and writes; the complete patch also updates the ready, valid and reset logic.
wire [PAYLOAD_WIDTH-1:0] selected_word = ready_reg ? input_word : back_reg;
wire stalled = valid_reg && !m_axis_tready;
always @(posedge clk) begin
back_reg <= selected_word;
if (!stalled)
front_reg <= selected_word;
// Ready, valid and reset logic omitted here.
endVerification evidence
Both designs passed 81 upstream test cases, a 20,000-cycle comparison, a directed full-buffer reset test and two ABC PDR cycle-equivalence proofs for this configuration. To check the reset test itself, we deliberately kept a valid flag set across reset. The test caught the stale word.
Reference implementation results
| Metric | Upstream | Patched |
|---|---|---|
| Routed cell area (µm²) | 871.948 | 742.672 |
| Setup slack (ns) | +8.7314 | +8.7472 |
| Hold slack (ns) | +0.1008 | +0.1165 |
| Directly registered outputs | 56/56 | 56/56 |
| Continuous stream (estimated pJ/transfer) | 1.7688 | 1.8355 |
Where the decision changes
Floorplan. At 54, 60 and 66 µm per side, the patch met the direct-driver requirement. At 57 and 72 µm, the router inserted a buffer on s_axis_tready. Reject those two implementations under the agreed criterion: only 55 of 56 bits retained direct connections, even though timing passed and area fell.
Workload. At the reference size, estimated energy per transfer rose 3.77% for continuous traffic. With one valid beat every eight cycles, it fell 13.72% when the source held the bus steady and rose 3.48% when the idle payload kept changing. These OpenROAD estimates cover one research library and one typical corner.
Download the 15 routed measurements (CSV) · Read the experiment and replay details
Review your own block
Bring one block, a testbench and the constraint that would make you reject a patch. We agree on that criterion before comparing the runs.
Try this on your block