Can a smaller AXI skid buffer preserve cycle behavior?
On a 60 × 60 µm floorplan, a GPT-6.2 Astra patch reduced routed standard-cell area from 871.948 to 742.672 µm² (14.83%). Both designs met the 100 MHz timing target and preserved all 56 directly registered output bits. Die dimensions stayed fixed.
What changed in the RTL?
The two payload banks share an input selection. When the downstream interface stalls, the output bank holds its word. The test target was a 32-bit AXI-Stream skid buffer with sidebands. We compared the candidate against upstream under the same typical Nangate45 corner and routing conditions.
The candidate passed 81 upstream test cases, a 20,000-cycle comparison and two cycle-equivalence proofs for this configuration. A directed test filled both entries under backpressure, reset the full buffer and checked that exactly one fresh beat emerged with its sidebands intact.
How sensitive is the result to floorplan size?
We reused each design’s mapped netlist, held placement density at 0.55 and used routing seed 42. Each row compares the two designs at the same die size.
| Die (µm) | Upstream (µm²) | Astra (µm²) | Area saved | Direct bits, Astra |
|---|---|---|---|---|
| 54 × 54 | 869.022 | 741.608 | 14.66% | 56/56 |
| 57 × 57 | 874.342 | 740.810 | 15.27% | 55/56 |
| 60 × 60 | 871.948 | 742.672 | 14.83% | 56/56 |
| 66 × 66 | 870.086 | 743.470 | 14.55% | 56/56 |
| 72 × 72 | 872.746 | 743.470 | 14.81% | 55/56 |
At 57 and 72 µm, routing inserted a buffer on the input-ready output. Both runs therefore missed the strict 56/56 direct-driver criterion despite saving area. At 60 µm, setup/hold slack measured +8.7314/+0.1008 ns upstream and +8.7472/+0.1165 ns for Astra.
Download all 15 routed measurements (CSV), including the Opus comparison, slack and output-driver counts. To check any area saving, compute 100 × (upstream area − candidate area) / upstream area using rows with the same die size.
What did the area saving cost in energy?
On the 60 µm floorplan, continuous traffic raised estimated energy from 1.7688 to 1.8355 pJ per transfer (+3.77%). At one transfer every eight cycles, holding inputs steady between beats reduced estimated energy by 13.72%. Changing those idle inputs instead raised it by 3.48%.
These are OpenROAD estimates at 1.10 V and 25 °C using extracted parasitics and zero-delay gate activity. The sweep covers one technology corner and routing seed. It does not measure silicon energy or establish a gain on other blocks.
Reproducing the experiment
The CSV supports independent checks of the reported area and timing figures. A fresh simulation and route requires the project replay scripts and pinned RTL. Request replay access.